279 research outputs found

    MICA: a Multichannel Integrated Charge Amplifier for the Read-out of Multielectrode Detectors

    Get PDF
    Abstract A 16 channel, fully parallel, CMOS integrated circuit including a preamplifier, a shaper and a discriminator, has been designed and succesfully teste

    A multi-channel integrated circuit for the readout of a microstrip gas chamber

    Get PDF
    Abstract The design and test of an 8 channel integrated circuit for the readout of the microstrip gas chamber and other multielectrode detectors are described. The circuit is composed of 8 identical channels, each providing the amplification and the shaping of the signal delivered by the detector. The peaking time of the shaper is 25 ns and the overall amplifier gain is 8 mV 1000 e βˆ’ . In addition to the analog output, each channel provides a TTL compatible digital output. The equivalent input noise is less than 700 eβˆ’ rms and the total dc power consumption is about 5 mW/channel. To avoid a baseline shift due to the tail of the current issued from the detector, an adjustable pole-zero cancellation circuit has been included

    Spectral and polarimetric characterization of the Gas Pixel Detector filled with dimethyl ether

    Full text link
    The Gas Pixel Detector belongs to the very limited class of gas detectors optimized for the measurement of X-ray polarization in the emission of astrophysical sources. The choice of the mixture in which X-ray photons are absorbed and photoelectrons propagate, deeply affects both the energy range of the instrument and its performance in terms of gain, track dimension and ultimately, polarimetric sensitivity. Here we present the characterization of the Gas Pixel Detector with a 1 cm thick cell filled with dimethyl ether (DME) at 0.79 atm, selected among other mixtures for the very low diffusion coefficient. Almost completely polarized and monochromatic photons were produced at the calibration facility built at INAF/IASF-Rome exploiting Bragg diffraction at nearly 45 degrees. For the first time ever, we measured the modulation factor and the spectral capabilities of the instrument at energies as low as 2.0 keV, but also at 2.6 keV, 3.7 keV, 4.0 keV, 5.2 keV and 7.8 keV. These measurements cover almost completely the energy range of the instrument and allows to compare the sensitivity achieved with that of the standard mixture, composed of helium and DME.Comment: 20 pages, 11 figures, 5 tables. Accepted for publication by NIM

    Giga view parallel image server performance analysis

    Get PDF
    Professionals in various fields such as medical imaging, biology and civil engineering require rapid access to huge amounts of uncompressed pixmap image data. Multi-media interfaces further increase the need for large image databases. In order to fulfill these requirements, the GigaView parallel image server architecture relies on arrays of intelligent disk nodes, each disk node being composed of one processor and one disk. This contribution analyzes through simulation and experimentation the behavior of the GigaView under single and multiple requests, and compares it to the behavior of RAID servers. It evaluates image visualization window access times under various parameters such as load factors and the number of cooperating disk nodes. Under single request, the GigaView image server can be modeled as a single high-throughput low-latency secondary storage device. Under multiple requests, the notions of utilization and maximum sustainable throughput define accurately the behavior of the GigaView

    Utilizing linked open data for web service selection and composition to support e-commerce transactions

    Get PDF
    Β© Springer International Publishing Switzerland 2016. Web Services (WS) have emerged during the past decades as a means for loosely coupled distributed systems to interact and communicate. Nevertheless, the abundance of services that can be retrieved online, often providing similar functionalities, can raise questions regarding the selection of the optimal service to be included in a value added composition. We propose a framework for the selection and composition of WS utilizing Linked open Data (LoD). The proposed method is based on RDF triples describing the functional and non-functional characteristics of WS. We aim at the optimal composition of services as a result of specific SPARQL queries and personalized weights for QoS criteria. Finally we utilize an approach based on the particle swarm optimization (PSO) method for the ranking of returned services

    XPOL-III: a New-Generation VLSI CMOS ASIC for High-Throughput X-ray Polarimetry

    Full text link
    While the successful launch and operation in space of the Gas Pixel Detectors onboard the PolarLight cubesat and the Imaging X-ray Polarimetry Explorer demonstrate the viability and the technical soundness of this class of detectors for astronomical X-ray polarimetry, it is clear that the current state of the art is not ready to meet the challenges of the next generation of experiments, such as the enhanced X-ray Timing and Polarimetry mission, designed to allow for a significantly larger data throughput. In this paper we describe the design and test of a new custom, self-triggering readout ASIC, dubbed XPOL-III, specifically conceived to address and overcome these limitations. While building upon the overall architecture of the previous generations, the new chip improves over its predecessors in several, different key areas: the sensitivity of the trigger electronics, the flexibility in the definition of the readout window, as well as the maximum speed for the serial event readout. These design improvements, when combined, allow for almost an order of magnitude smaller dead time per event with no measurable degradation of the polarimetric, spectral, imaging or timing capability of the detector, providing a good match for the next generation of X-ray missions.Comment: accepted for publication at Nuclear Inst. and Methods in Physics Research Section

    Herpes Virus Fusion and Entry: A Story with Many Characters

    Get PDF
    Herpesviridae comprise a large family of enveloped DNA viruses all of whom employ orthologs of the same three glycoproteins, gB, gH and gL. Additionally, herpesviruses often employ accessory proteins to bind receptors and/or bind the heterodimer gH/gL or even to determine cell tropism. Sorting out how these proteins function has been resolved to a large extent by structural biology coupled with supporting biochemical and biologic evidence. Together with the G protein of vesicular stomatitis virus, gB is a charter member of the Class III fusion proteins. Unlike VSV G, gB only functions when partnered with gH/gL. However, gH/gL does not resemble any known viral fusion protein and there is evidence that its function is to upregulate the fusogenic activity of gB. In the case of herpes simplex virus, gH/gL itself is upregulated into an active state by the conformational change that occurs when gD, the receptor binding protein, binds one of its receptors. In this review we focus primarily on prototypes of the three subfamilies of herpesviruses. We will present our model for how herpes simplex virus (HSV) regulates fusion in series of highly regulated steps. Our model highlights what is known and also provides a framework to address mechanistic questions about fusion by HSV and herpesviruses in general

    First light from a very large area pixel array for high-throughput x-ray polarimetry

    Get PDF
    We report on a large active area (15x15mm2), high channel density (470 pixels/mm2), self-triggering CMOS analog chip that we have developed as pixelized charge collecting electrode of a Micropattern Gas Detector. This device, which represents a big step forward both in terms of size and performance, is the last version of three generations of custom ASICs of increasing complexity. The CMOS pixel array has the top metal layer patterned in a matrix of 105600 hexagonal pixels at 50ΞΌm pitch. Each pixel is directly connected to the underneath full electronics chain which has been realized in the remaining five metal and single poly-silicon layers of a standard 0.18ΞΌm CMOS VLSI technology. The chip has customizable self-triggering capability and includes a signal pre-processing function for the automatic localization of the event coordinates. In this way it is possible to reduce significantly the readout time and the data volume by limiting the signal output only to those pixels belonging to the region of interest. The very small pixel area and the use of a deep sub-micron CMOS technology has brought the noise down to 50 electrons ENC. Results from in depth tests of this device when coupled to a fine pitch (50ΞΌm on a triangular pattern) Gas Electron Multiplier are presented. The matching of readout and gas amplification pitch allows getting optimal results. The application of this detector for Astronomical X-Ray Polarimetry is discussed. The experimental detector response to polarized and unpolarized X-ray radiation when working with two gas mixtures and two different photon energies is shown. Results from a full MonteCarlo simulation for several galactic and extragalactic astronomical sources are also reported

    Saliency maps for finding changes in visual scenes?

    Get PDF
    Sudden changes in the environment reliably summon attention. This rapid change detection appears to operate in a similar fashion as pop-out in visual search, the phenomenon that very salient stimuli are directly attended, independently of the number of distracting objects. Pop-out is usually explained by the workings of saliency maps, i.e., map-like representations that code for the conspicuity at each location of the visual field. While past research emphasized similarities between pop-out search and change detection, our study highlights differences between the saliency computations in the two tasks: in contrast to pop-out search, saliency computation in change detection (i) operates independently across different stimulus properties (e.g., color and orientation), and (ii) is little influenced by trial history. These deviations from pop-out search are not due to idiosyncrasies of the stimuli or task design, as evidenced by a replication of standard findings in a comparable visual-search design. To explain these results, we outline a model of change detection involving the computation of feature-difference maps, which explains the known similarities and differences with visual search
    • …
    corecore